Stuart Pittaway
Stuart Pittaway
Hi @moscito1010 The controller shouldn't be rebooting - in fact the latest release is the most stable - I'm over 50 days uptime and counting. Can you try programming the...
If you are powering the controller using the +5V/2Amp connection on the PCB, this shouldn't be a problem. Did removing the LCD fix things?
Thank you for testing - could be a potential issue with the controller circuit board (its design). Can you tell me what length cable you used (6 pin ISP cable)...
150cm cable is very long!! I normally only use a 10cm cable.
There is a limit of 128 modules in the system, so technically 8 banks are possible - although I don't think anyone has done this yet!
Communications has always been a problem with the module design - I do plan to fix this, but it would mean existing hardware won't work. The best solution currently, is...
You can put the controller into the middle of the "string" to avoid having a long cable run between the last cell and the controller. This does depend on the...
What version of Victron firmware are you running? People have seen this alert change behaviour between Victron firmware releases.
> @stuartpittaway did you obtain documentation on the DVCC/Victron CAN-bus implementation or was it reverse engineered? Victron provided some documentation for me, although there were some inaccuracies in it.
Ok - in which case I would need to get a copy of the log files from the USB port on the ESP32 when this scenario occurs - unfortunately this...