Have you played with the default setting of 4? If not, can you try increasing it by steps of 4 until the problem goes away, or you hit ~30.

If you have a good SWG reading, you can calibrate many SWG to suit that calibration. (Have to check the manual for that). I personally don't trust pool shops in...

PPM is taken from the RS485 message the SWG sends back to AquapureD. It shouldn’t require any code changes even with the PPM values used in Australia. The max value...

The measurement works accurately for Haywood / Goldline / Pentair & Jandy SWG, so I'm really surprised that Zodiac would use something different. This is how it's calculated. ```Received AR...

MQTT fullstatus should show check cell message. #8 is check cell, this is the same as clean cell. https://github.com/sfeakes/AqualinkD/wiki#MQTT If your not seeing that, can you post the serial_debug logs...

Thanks for catching that, the code is there, just forgot an example entry in the config file. LOG_FILE = /dir/file.log

> Looking at that link that’s my chlorinator so connecting A & B to A & B on the RS485 board? Yes that's correct. Just two wires between Chlorinator and...

Set the chlorintor controller to either Jandy setting. But if you didn't see any ACK from the PROBE then their might be more to it than just that setting. This...

According to the below, it's 10 Volt DC that you need to supply. https://www.jandy.com/~/media/zodiac/global/downloads/0748-91071/6919.pdf Since the chlorintor has it's own power, I'm sure the power over the RS485 bus is...

One more edit, reading the document on your chlorintor, it looks like it will only try to connect to the RS485 for the first 20 seconds after the initial power...