Michael Stegen

Results 117 comments of Michael Stegen

For programming i used Si4010_NVM_Burn_CL.exe called by a batch file. I found it programmed the fastest. Not sure anymore where i got that from. It's in a folder called Si4010_NvmProgUtil...

It's been a while, but you'll need to install Silicon Laboratories wireless development suite, and install the KEIL compiler. Then also install the example files for the SI4010, see here:...

Hi, This should not happen, Every 2 seconds the SmartEVSE will receive a measurement from the Sensorbox, and if one of the phases is measuring above the Mains current (usually...

Ah, yes the E350 is unfortunately not supported. Weird that it works, i have never seen a E350 with a (D)SMR 5 telegram. For what it's worth, i told the...

It's the same as the one i once had. The ZMF110CCtFs2 model, look at the top left corner..

@poelie83 Great news! @IgorYbema It would require some code changes to the SmartEVSE software, in order to make this work on this smart meter. The SmartEVSE will increase/decrease the chargecurrent...

Hi, The re-init was added to fix garbled LCD screens. It sometimes happens with big contactors that are next to the SmartEVSE. Even when there is no load connected to...

Hello Andrej, Thanks for your suggestions, i'll most likely implement your changes in the next HW rev of the LCD board.

Hi, Could you please let me know the software version the SmartEVSE's are running? When there is noting connected to the CP pin, it should measure +12V. When a car...

When at +9V/-12V 1kHz, the EV should detect the signal, and initiate the charge by pulling it to 6V. Have you checked the charge cable/plug for water ingress? Ofcourse i...