I'm closing this issue as this should now be resolved - please let me know if you still have wifi reboot problems

Hi, the log file isn't overly long, ``` I (33881) diybms-rules: Set error 4:WaitingForModulesToReply I (33882) diybms-rules: Set warning 7:ChargePrevented I (33882) diybms-rules: Set warning 8:DischargePrevented ``` These lines at...

Ok, thanks for that - there isn't anything written to the logfiles except for "ModuleInconsistantCodeVersion" which won't prevent charging/discharge. All the code for the Pylon 485 is in pylon_rs485.cpp -...

``` [180494][D][pylon_rs485.cpp:262] handle_rx(): [diybms-pylon485] Pylon Charge Mgmt - Chrg limit: 54400mV, Dischrg limit: 48000mV, Chrg curr: 751mA, Dischrg curr: 2000mA, Flags: 0xC0 ``` Ok, so ignoring the "mA" units in...

Hello, generally charging a cell/battery under 0C is a bad idea as the cells chemistry can be damaged - what cells are you using?

Hi @lorenzo620 is this the same user as @lorenzo6201 ? Thank you for the suggestions about pre-charge setup and access point options. They are both good ideas. I've so far...

> How about the meningd firmware? That firmware rocks. I've not personally used it - when it was forked from the original code it was very difficult to re-integrate back...

Ok, randomly disappearing temperature values and also discharge prevented messages are a likely indicator that communication messages are being lost and the controller assumes "zero" voltage or "no temperature" for...

Just found this on Google... [Sol-Ark CAN Bus Protocol V1.3.pdf](https://github.com/user-attachments/files/20442602/Sol-Ark.CAN.Bus.Protocol.V1.3.pdf) Doesn't appear to mention the Maximum values in any of the data it wants - DIYBMS is sending all the...

Did you check for communication errors? How are the cells attached to the monitoring board? Have you tried selecting non-deye inverter option on the charge screen?