Stuart Pittaway
Stuart Pittaway
Ok great. What I'm seeing is the out of sequence error counts being more than zero. This indicates that communication is getting lost in the cell modules and probably when...
Right, this will be painful with so many modules but could you drop to a lower baud rate - you will need to reflash all the modules to achieve this....
Try the 5K option. I think the problem you have is lost data rather than not supporting 128 cells. You shouldn't have missing gaps in the chart, which is why...
You can also take a look at the module page and look at the bad packet counts. Send a screenshot of that over.
Dropped you a message on Patreon, if you can upload some more screenshots please
Hi @Leodien CAN register 4220 is only written to when using the PylonForce H2 protocol - is that what you are running? The code below is what transmits that message...
Yes - DynamicChargeVoltage should always have a value - however don't forget that if "IsChargeAllowed" is false, the BMS has detected a state which it considers isn't safe for charging...
Hello, this is a commonly reported issue. Can I ask what WiFi access points do you use? Are you using a mesh network?
Ok, lots of people had problems with Fritzbox routers when running in mesh configuration. At the moment I don't have a fix for the WiFi issue, I'm not sure if...
> @laserranger3000 A new firmware with the WiFi fix has just been released. Hopefully, fingers crossed! How has the testing gone @laserranger3000 ?