InsanityAutomation
InsanityAutomation
@petaflot can you verify the open PR resolves the issue on youre end?
> > Generic ExtUI functions should have access to … custom user menus … > > That's just not an ExtUI thing. Each LCD has to implement custom menus its...
I think this is a hole that needs to be closed to a degree. There are too many places to inject gcode and safety related commands should not be able...
> I was trying to add a physical button emergency stop button to a laser machine. I didn't want to run power wires to the control panel, so I'm trying...
I made some changes here that seem to work as intended in the sim as far as I can take it... Some elements require physical testing beyond the sim. I...
There is a config option not explicitly spelled out that should be able to achieve what you want - ``` #if ENABLED(SLOW_PWM_HEATERS) && !defined(MIN_STATE_TIME) #define MIN_STATE_TIME 16 // MIN_STATE_TIME *...
When the question on host prompt support to allow filament runout and such to function went unanswered, I just moved to the BigTreeTech displays anyway, as theyre not only dual...
If I can get one I will definitely add it. @tinymachines-3d has offered an Ender 7 and CR10 Smart first, and I have code to reference for the CR5 which...
Not yet, CR10Smart is here now, CR5 arrives next, then the CR200B will be behind it. We did get the new revision screen in it working with the Sermoon /...
This is expected, and ensures a more accurate probe with the capacitive sensor. Bed heating will cause deviation in the trigger point. Since the intention is to probe once accurately...