Marlin icon indicating copy to clipboard operation
Marlin copied to clipboard

Auto leveling make pauses and shows "Bed heating" cr10s Pro V1 ( capacitive sensor )

Open shifubrams opened this issue 3 years ago • 7 comments

Description

I upgraded from DW6 to DW7.4 and now the leveling is taking lot of time. Before each point ( 25 ) it waits the temp of the bed and shows "bed heating" but the bed temperature is stable. Is this a known issue or it is a wanted behaviour ?

Steps to Reproduce

  1. install DW4.7 on cr10s Pro V1
  2. run a bed leveling
  3. see the pauses between each points Expected behavior: shouldnt pause on each point. ( too long ) Actual behavior: make a pause before each point

Additional Information

I installed from the .hex file

image

shifubrams avatar Jul 04 '21 09:07 shifubrams

Same issue with TH3D EZABL 18mm on Ender 6

CenGo86 avatar Jul 05 '21 19:07 CenGo86

This is expected, and ensures a more accurate probe with the capacitive sensor. Bed heating will cause deviation in the trigger point. Since the intention is to probe once accurately and store to eeprom, this should only cause a delay when re-calibrating due to some change.

InsanityAutomation avatar Jul 07 '21 20:07 InsanityAutomation

Hi, Can i turn off the stop at the level?

DerRudi79 avatar Aug 02 '21 06:08 DerRudi79

CR-10S Pro updated today, it does this with EVERY print. This is not acceptable nor normal. I did a PID tune on the hot end and it heats up irregularly, more deviation that before on 7.3.1 from Tiny Machines. A few degrees isn't going to mess up anything, but the time this is taking is over 15 minutes, which used to take maybe 1-2 minutes. Please fix was was done from 7.3.1 to 7.4 in this regard. Thanks Screen Shot 2021-08-27 at 6 54 38 PM Screen Shot 2021-08-27 at 6 59 37 PM Screen Shot 2021-08-27 at 6 54 38 PM Screen Shot 2021-08-27 at 7 03 21 PM

MarcusBenjamin avatar Aug 28 '21 00:08 MarcusBenjamin

I was happy to have found this post, since I have been questioning what happened to my CR10S Pro (v1 with the stock capactive probe) after upgrading to DW7.4, since now an ABL takes 15-20m, due to waiting for the bed during probing. During ABL the printer pauses ever 1 or 2 probe points due to the heating, which seems to demand perfection now. I had run the bed PID tune multiple times, but it did not help, so I hope this is fixed in the next release.

To avoid the 15-20m delay in starting a print, I no longer ABL every time and use the stored mesh unless I have a very large print (commented out the G29 I was using):

G28 ;Home ;G29 ; initiate z-probing M420 S1 Z2 ;Enable ABL using saved Mesh and Fade Height

Edit/Update, I'm also seeing the hot end temp fluctuations since upgrading. But mine will stabilize after about 10m like magic, I think part of it has to do with the ABL which I had to re-enable due to some failures with loading the saved mesh which halts the print (has happened at least twice since upgrading to 7.4).

Can anyone tell me what the last stable version prior to DW7.4 was (for a CR10S Pro with the stock inductive probe)? I was using DW6 before going to DW7.4 and it was good, and could just roll back to that, but I'd prefer to move to 7.x if possible.

MyStoopidStuff avatar Sep 26 '21 08:09 MyStoopidStuff

I believe this should be closed. I updated from DW7.4 to DW7.4.3 and the issue has gone away.

Tested by community.

thetailwind avatar Nov 07 '21 15:11 thetailwind

I'll make a sweep through and close stuff in a few days, trying to finish up adding Sermoon and Ender 7 support as well as a few other tidbits in the next few days!

InsanityAutomation avatar Nov 07 '21 16:11 InsanityAutomation