John
John
Okay, how about just the add-on board with the cs pins changed in the config?
It sounds like the meters are damaged unfortunately. I would send you a replacement, but I do not have any in stock at the moment.
@BrandoCommando, @eaconner, @XtremeOwnageDotCom New meters coming your way to test.
> All I can say, is good luck to the both of you. > > I never received a response from my PM, nor an update here (after 3 months)....
> Thank you. I have checked your files. And the give.the same error on jlcpcb.com. When I want to order them When you are exporting via the CAM processor, is...
Thanks for following up with this. I'll take a look at what needs to be changed to fix it. The version for the 6 channel meter adds calibration fields, and...
Hi Alex, I realize the documentation is a bit confusing. It does need to be updated. For dual pole circuits, each hot is going to carry half of that load...
Sorry I wasn't able to reply to you sooner! In your config you have a `multiply: -2` for power on CT1, CT2. If you're getting a negative value, the fix...
It's very odd to see that much of a difference between the 2 voltage readings when they are coming from the same AC transformer. I would recommend calibrating the voltages...
@Cougar that is very interesting. I haven't observed that behavior myself. You may be onto something with the reset timing. Are you doing a reset via software or power cycling?...