Results 90 comments of John

Okay, thank you for explaining, and providing your config. Please try changing gain_pga: to 1x. 2x should only be used when the amperage output of the CT is too low,...

Which AC transformer are you using for the voltage reference?

> Hello @CircuitSetup , What exactly do you mean? The trasformer is one I have my own, exactly this model: https://www.amazon.it/dp/B09J4RDSLZ Unfortunately this transformer will not work since it is...

Yes, the calibration value in your config.yaml for voltage must be increased so volts match your smartplug. Since you have the values already, you can calculate what it should be...

If voltage_cal was 1034.7 in your config when the output was 160.5V, then: (220.4/160.5) * 1034.7 = 1420.86 (round up to 1421) Volts B should be the same, and will...

It's okay! I realize it's a bit confusing! Since 1034.7 is power (not voltage) it shouldn't be part of the calculation. If voltage_cal was the default 7305 in the screen...

yes, just use 10031 without decimal numbers

> Thanks @CircuitSetup , now it looks better, I'm searching something better to measure Volts to be more accurate. Meawhile, why there are two "Volts" readings? A and B? The...

Sure! Submit a pull request and I'll add it, assuming it works :)

I'm sorry the process is so confusing. Are you installing on an ESP32 for the single phase or 6 channel meter? Do you want to use EmonESP or ESPHome? EmonESP...