I've not had anyone else report this as an issue, can you share some more details on the list_charge_slots and also what other sensors you have?

For Ohme you need to configure differently, the new ohme integration is now supported https://springfall2008.github.io/batpred/devices/#new-ohme

No Charge isn't a real state its a charge where the battery level isn't increasing, so scheduled charge is expected.

The YAML you provided was different, it looked like this: ![Image](https://github.com/user-attachments/assets/47a586a1-2cb6-4a7a-acba-db3ea3e5c624) However if I disabled the freeze charge then I get to: ![Image](https://github.com/user-attachments/assets/37544dbe-de1b-45a0-9841-1cf6c3f6aa57) I'll look to see about the clipping...

Notice that the freeze charge has no impact, as no grid charging will occur in that time period as the battery already reaches target. I also notice a period of...

You have an inverter limit of 5000 and an export limit of 5000 A battery rate max of 3600 Your peak PV in this plan is 1.65 kWh at 14:00-14:30...

I'd need the debug yaml from before the clipping to debug this further, please try to capture one another day On Mon, 24 Mar 2025 at 19:32, parklife200 ***@***.***> wrote:...

This appears to be same issue I already fixed with ticket 1206 Updated plan ![Image](https://github.com/user-attachments/assets/78728597-1135-4192-9bea-4719367ff8e6)

This should be on all the time, not sure why not. I'm not sure if I count it as a GivTCP bug or not....

Documentation updated for now