Lars Kasper
Lars Kasper
Dear Darius, This is a good point, and was on our mind for a while (also for another format, [ISMR]MRD). The issue, as so often, is time and resources, so...
Dear RGM79pile, Thank you for using PhysIO! I wasn't aware that the custom format only supports integers, did you confirm this? In the code, it uses `load(log_files.respiration, 'ascii');`, which should...
Dear Fidel, Yes, could you please share the Physlog files with me to reproduce the error you are experiencing. From your description it's not quite clear to me what is...
Dear Claire, Thank you for trying out this functionality and giving such a detailed report. Your strategy is perfectly sound, and I apologize that the PhysIO interface is clunky for...
Dear Yonghyun, My apologies for the late reply, I am on parental leave now, so things might be a bit slow in general on my end. I haven't had time...
Dear Leyla, Could you please try to replace `matlabbatch{1}.physio` by `matlabbatch{1}.spm.tools.physio` in all lines of your script? All the best, Lars
Dear Leyla, I think this is a longstanding difficulty when installing PhysIO...it should automatically copy the tapas/PhysIO/code folder to spm12/toolbox/PhysIO, but unfortunately, this doesn't always work... I guess as soon...
Dear @aishaejazz, Typically, `.puls` files are from the Siemens system, acquired via `ideaCmdTool` manual recording. You could open them with any text editor to confirm the structure that is described...
Dear @aishaejazz Which of the two plots do you find weird? The second one looks actually OK from my end, but you will have to use a horizontal zoom on...
Dear Ruwan, If you select the respiratory volume per time (RVT) model as an output, and then use the original computation method by Rasmus Birn et al. that is based...