Lars Kasper
Lars Kasper
Dear Michael, somehow I cannot see the screenshot. Could you try to upload it to github again, please? I just reopened your issue. In general, did you include the `multiple_regressors.txt`...
Dear Michael, the `.m`-file looks correct to me, so this behavior seems strange. May I ask 1. Do the `multiple_regressors*.txt` files look reasonable for each run? (You could also load...
Dear Michael, you didn't misunderstand at all, my question about the GLM batch was a follow-up, because there was nothing conspicuous I could see in the PhysIO batch. Looking at...
Dear @negorova, While it sounds similar, this might actually be a different issue. Which scanner vendor are the logfiles from (Siemens/Philips)? If it is Siemens, one potential reason could be...
Dear Fidel, I believe the best way to go about this, is to change the `Position` of the figure, e.g., `set(verbose.fig_handles(k),'Position', [10 10 widthInPixel HeightInPixel]`. You might also adjust it's...
Dear Fidel, This was just a placeholder, you have to define values for these variables before, e.g., `widthInPixel = 1400; heightInPixel = 875;`. All the best, Lars
Dear Caroline, Thank you for being a loyal PhysIO user - I am happy to hear it has been a useful tool to you for many years. Also, my apologies...
Dear @irmakoz1 , My apologies for the delayed reply. Did you find a solution? Typically, exporting to `.mat` files should work and choosing the "BioPac" option for the vendor. You...
Dear @reemTamimi, I would suggest you start from one of the example scripts and data that you can download as described [here](https://github.com/translationalneuromodeling/tapas/tree/master/PhysIO#getting-started). In your case, `tapas_physio_example_siemens_vb_ppu3t_sync_first_matlab_script.m` might be a good...
Dear Imam, Thank you for using the PhysIO Toolbox, happy to hear it worked well on Philips data! In principle, you should be able to use the `.log` data from...