My 30 sec statement on the 0% part of the bounce, was an estimate at time by counting the number of messages. You have 228 total messages between the SWG...

Something very interesting, right in the middle of the 0 bounce. ``` 0x10|0x02|0x00|0x01|0x3f|0x00|0x52|0x10|0x03| *1) 0x10|0x02|0x50|0x11|0x00|0x73|0x10|0x03| 0x10|0x02|0x00|0x16|0x25|0x00|0x00|0x00|0x4d|0x10|0x03| 0x10|0x02|0x80|0x00|0x92|0x10|0x03| 0x10|0x02|0x0a|0x02|0x00|0x14|0x00|0x00|0x00|0x32|0x10|0x03| *2) 0x10|0x02|0x0a|0x03|0x00|0x20|0x20|0x41|0x71|0x75|0x61|0x50|0x75|0x72|0x65|0x20|0x32|0x35|0x25|0x20|0x20|0x6f|0x10|0x03| 0x10|0x02|0x60|0x00|0x72|0x10|0x03| 0x10|0x02|0x33|0x30|0x75|0x10|0x03|0x00|0x00| 0x10|0x02|0x00|0x01|0x00|0x00|0x13|0x10|0x03| 0x10|0x02|0xa3|0x53|0x08|0x10|0x03|0x00|0x00| 0x10|0x02|0x00|0x01|0x3f|0x00|0x52|0x10|0x03| *3) 0x10|0x02|0x50|0x11|0x00|0x73|0x10|0x03| 0x10|0x02|0x00|0x16|0x25|0x00|0x00|0x00|0x4d|0x10|0x03| ``` Message...

Yup, that’s what’s happening. As for the bad packets, I just read yours manually so didn’t do any checksum checks, I’ll run your raw logs through my parser to check,...

This is odd behavior, but I think you may have multiple things going on. First you should turn off SWG and Extended packet detection in AqualinkD config. Use the following...

The “select line” is the message the control panel sent Aqualinkd. It simply telling the display to highlight that line. Aqualink is not sending any commands. When I said wiring,...

That should eliminate any issues, I’ve read about them and I think one other person is using one. All the pool equipment is very non specific as to what’s terminated...

This part of that message `0x10|0x02|0x50|0x11|0x41|0xb4|0x10|0x03|` is the control panel telling the SWG to set to 65% (is 65% what your SWG is set to) ? 0x50 is SWG. 0x11...

The pump (like SWG) needs constant communication with the control panel, if that is lost, both will go into a “local control state”, which means any local timers (If they...

It does seem to depend on hardware version as so what is and isn’t terminated. Seems originally hardware was not terminated allowing people to daisychain devices. But that probably got...

Remember that the control panel also powers the RS bus and even some circuitry of some devices. (Like the interface board of a SWG). On the wiring I assume you’ve...