RevK
RevK
It may be, there is a lot of S21 status? But not one I know as yet.
I'm beginning to wish I had not added this reported value, and maybe I'll make it only appear if there is an explicit setting in future.
Tricky as we send HA config at start and don't update when you turn on/off faikin auto mode. Not sending once we have told HA we have it just causes...
It is reverse engineered, but I think we have it right. For one way, turning on the dump setting should provide some logs on MQTT. If you can post those...
There is a debug as well, which may help.
You can send a command from MQTT. There is something in the manual pages for that.
Unless you can find another S21 message that tells us what you want, the faikin won't be able to tell. Maybe there is a system wide demand control or something...
The S21 messages use a fun range of different codings. I'll check this one shortly and let you know.
OK for this one, the first character in G7 is demand, and is coded as the character '0' (0x30) plus a number 0 to 100. Econo mode is second character,...
Some of the S21 has been documented but not entirely up to date, and it would be a good project to get a lot more up to date. No I...