Lars Kasper
Lars Kasper
Dear Shahin, I have now updated the reader and retrieve decent results for your example data with batch `.m` file pasted below: 1. I will make the code available in...
Dear Shahin, Sorry, I must have overlooked this comment. Did you try setting `defaults.ecgChannel='v3';` and it didn't work? Or do you mean that the option is not mentioned in the...
Dear Amijas, I can reproduce the error and your input data looks fine (both `.txt` files) on first glance (first screenshot). There seems to be an issue with the respiratory...
Dear Darius, thank you for trying out PhysIO! BIDS should be read in alright, I don't think you would have to convert it. Could you give me some more details...
Dear Darius, indeed, it looks like the respiratory curve is missing, but it also looks as if the cardiac raw trace has a very long cycle length (3 seconds). What...
Dear Sara, very nice to hear from you, and to see that you are still working with PhysIO! I hope everything is well despite the toll that the pandemic has...
Dear Sara, you are right, everything (task+PhysIO modeling) goes into the same first level GLM. All the best, Lars
Dear Sara, I will have a look at the data you sent, thank you for preparing it! 1. From a first glance, the F-contrasts for the noise rois indeed look...
Dear Sara, sorry for the delay, end-of-year wrap-ups everywhere. Thank you for sending the individual session contrast reports, I find them much easier to interpret. So the combination of the...
Dear Sara, It's great you are making continued use of the PhysIO Toolbox. I think the warning message about the orientation is not worrisome, you did the right thing, checking...