Andrey G

Results 53 comments of Andrey G

@mck1117 https://github.com/mck1117/wideband/pull/314 . But needs more testing.

[two_heat_up.zip](https://github.com/mck1117/wideband/files/10739707/two_heat_up.zip) @mck1117 started from ~6V then rise to 12.5V, wait until heated.

I believe this is because of long wires to power supply and supply capable of 3A only.

@mck1117 me, Andrey and one more beta-tester have f1_dual (rev0) boards. So I'd like to have this code in master. On other hand I can supply modified FW to few...

Also. In case of `Preheat` state target `heaterVoltage` is 2V. For dual boards it is possible that WBO is powered while supply voltage is not applied to sensors (supplied through...

See comments at https://github.com/mck1117/wideband/pull/140

Or maybe this is caused by rapidly increased heater PWM? Unlikely. Issue can also be solve by using hysteresis for `underheatESR` thresholds. ![Screenshot from 2023-03-22 10-42-17](https://user-images.githubusercontent.com/28624689/226833679-d2c9651a-fe87-4f33-be01-c788431ca19b.png) [lsu42_heating.zip](https://github.com/mck1117/wideband/files/11037524/lsu42_heating.zip)

Pump control enabled only after sensor reaches `targetESR` ![Screenshot from 2023-03-23 00-43-54](https://user-images.githubusercontent.com/28624689/227045414-216cc584-3c30-4983-9423-02c0a07da82c.png) [lsu42_heating_mod.zip](https://github.com/mck1117/wideband/files/11044969/lsu42_heating_mod.zip)

Looks like Nernst voltage is too low and AC component is clamped. This gives us lower ESR than actually it is. When we start feeding pump with some current Nernst...