Francesco Casella
Francesco Casella
@adrpo, @arun3688 can you please help @BasilioPV with that? Thanks!
The plot thickens: the result actually depends on the operating system (?!?) On Windows 11, I get this outcome: ``` The initialization finished successfully without homotopy method. Homotopy solver Newton...
Here is an MWE: ```modelica model Test Modelica.Electrical.Spice3.Basic.Ground ground; Modelica.Electrical.Spice3.Sources.V_pulse v(V2 = 5, TR = 0.1e-12); equation connect(v.n, ground.p); annotation( experiment(StopTime = 1e-11, Interval = 5e-15, Tolerance = 1e-7), uses(Modelica(version...
OK, maybe I've got a clue on the MWE. Logarithms are actually not involved at all. This is an excerpt of the source code of the Modelica.Electrical.Spice3.Sources.V_pulse model: ```modelica ......
In any case, the usage of the V_pulse model is fishy, I'll discuss that within MAP-Lib
Here is an MWE that reproduces the issue: ```modelica model MWE import SI = Modelica.Units.SI; SI.Voltage v; parameter SI.Voltage V1 = 0 "Initial value"; parameter SI.Voltage V2 = 0 "Pulsed...
Huge discussion, see modelica/ModelicaStandardLibrary#4478 and modelica/ModelicaStandardLibrary#4479. My suggested action at the moment: leave Modelica.Constants.inf alone and just fix the defaults for the Spice3 models with something appropriate, see PR modelica/ModelicaStandardLibrary#4481
After lengthy discussions in the MA context, I came to the conclusion that the best course of action for the moment being is that we change the OMC-specific implementation of...
Should be fixed by https://github.com/OpenModelica/OpenModelica-ModelicaStandardLibrary/commit/adcbfc535c3b8ab0826eb21f59c268c40a473125, let's check if https://libraries.openmodelica.org/branches/master/Modelica_4.1.0-beta.om/Modelica_4.1.0-beta.om.html is improved when the test job runs again
Yes, indeed all the 6 models mentioned in the first post now pass verification. Thanks!