Francesco Casella

Results 1758 comments of Francesco Casella

I agree I prefer solution 1. Andrea also mentioned another possible solution at some point, namely the reference bus only setting the phase of the voltage. Was that dismissed?

@ceraolo suggests that a fairly standard practice in grid modelling is to connect the slack node to a strong generator, so the configuration made possible by this ticket should be...

Also note that all tutorial models using generators are now complaining that componentPF.SNom and componentPF.UNom have no value. Apparently the redeclare is causing the parameter propagation to be lost. We...

I discussed this with @ceraolo and @AndreaBartolini. There are multiple issues at stake here. The most important is that these tests are set up with option GlobalSteadyStateFixedPowerFlow, which is meant...

In any case, we agreed with @ceraolo that it would be nice to show one example in the tutorial where the PF result and the actual initial steady-state value of...

We currently store the results of the latest released version here: https://github.com/PowerGrids/PowerGrids-ref I need to update the repository so that there are separate reference results for each released version.

> AFAICU, IEEE14busStaticNetwork should produce the same results ad IEEE14busPowerFlow. This is not necessarily the case. The EPF uses PV nodes with fixed active power and voltage, and PQ nodes...

To be honest, I'm not sure I see the advantage of that over just looking at the MW outputs. If you set the base power to 100 MVA, the difference...

The section about using the library is now complete. I just need to add the section on the EPF