I m having a problem with my heatbed. My skr pro card is attached to a ssr and to a silicon heatbed. The problem is, as soon as i turn...

> > I m having a problem with my heatbed. My skr pro card is attached to a ssr and to a silicon heatbed. The problem is, as soon as...

> Do you use a 12v DC heatbed? You have the wrong SSR when you use the DA this means DC input for control and AC for output. DD means...

> When you use a 12v Silicon Heatbed then is the Fotek DA the wrong SSR. I had the same problem with a 110-230V AC Heatbed, then I changed the...

the silicon bed is 220v 250W. my ssr has a led as well. it turns on as soon as i turn on the printer and start heating up the bed....

> @turnali > You did find this issue. Did you read it? Did you understand the consequences? > > Did you try to connect the SSR with the opposite polarity?...

> Can you measure up the bed output from the board without ssr? > At the Board are leds for the outputs, when the output is green , then is...

I was able to stop the heating by itself problem but this time the bed doesnt heat at all :))). Everything works fine on the board; output connections, current, leds.......

> > I was able to stop the heating by itself problem but this time the bed doesnt heat at all :))). Everything works fine on the board; output connections,...

> The back part of the SSR should be a grounding plate. So if the connection on the other side is a Hole use that one. Just because the connection...