Olli Salonen

Results 17 comments of Olli Salonen

Yep, the LoRaWAN device is not compatible with wMBus as you found out. I've got the Zenner Minomess that looks exactly like the Zenner marketing picture (wM-Bus C1 Mode). The...

Yes, I know. :) I'm not saying it should be done, but just to raise an idea and if any dev finds it interesting maybe it'll end up in the...

Moro Sami, You can get the same energy usage out from HeishaMon as you can get from the original Panasonic unit. The S0 connection is for an external meter that...

Oh yes, you're correct. I'm counting the energy usage per day in Grafana on my system. I have an external M-Bus capable kWh meter in front of my heat pump...

in HeishaMon/webfunctions.h the size of the field is limited to 40: char wifi_password[40] = "";

Fairly sure no-one checked the actual max length specification allows. It's an easy fix to change from 40 to 63 though. I can enter more than 25 characters in the...

Yeah, I was last week trying to write this open bit-by-bit to find similarities. Separation between IDU and ODU codes is one possibilty indeed. I also have here one J-gen...

Interesting. My model string is: 62 D2 --- 0B 41 54 --- 32 D2 --- 0C 45 55 Address 93: 0xD2 61 Address 94: 0x54 41 0A Address 95: 0xD2...

Should be close to 100%. I've got a J-gen 5kW split unit here and "Correct received data: 99.83%".

@MiG-41 I'm aware of the base pan heater and I have one in my unit (it's more or less mandatory here in the north). However, to lead out the water...