Jimmy Everling
Jimmy Everling
I've added a check for invalid total energy values, and released v1.0.11. Any changes with a delta greater than 500 kWh are discarded.
If you check the Home Assistant log, what is the error message reported by integration? Btw, you are not trying to connect an Aquarea device?
@Segran think you forgot the actual logs :) Or at least I can't see them...
Hmm, interesting, you don't seem to have the `packaging` package. What version of HA do you have?
Hi @frenck, I'll try to fix this as soon as I have some free time.
Hi @Dominic-070, As far as I know, you can't change the number of allowed phases from the configuration. But you can change the current limit by calling: ```yaml service: garo_wallbox.set_current_limit...
Hi @codyc1515 The problem is that we are at the mercy of the Panasonic API and especially if you have the energy/power sensor active. That call can be extremely slow,...
The best workaround to increase the responsiveness is locking the API IP to a single IP so the HVAC and HA are connected to the same server. This did not...
Yes, looks like they made some changes again... I can't even login in to the app it just gives me a "Loading..." screen Edit: it was just dead slow...
The integration should still work, I tried authenticating using the same procedure as the integration. I used the same account as I used with the app (I used the SMS...