Per Skenhall
Per Skenhall
Closely following this thread and others like it as I have a similar setup (2 inverters, 1 battery & 1 smart meter), but when using this integration only one inverter's...
> @skenhall, I had a similar problem at the beginning because I had `slave: 1` at the beginning but in my configuration I had to set it on `slave: 2`....
Actually to follow Modbus terminology it is Home Assistant and this integration that is the master. According to the Huawei Modbus Interface Definition, it is then the SDongle that is...
> Actually to follow Modbus terminology it is Home Assistant and this integration that is the master. According to the Huawei Modbus Interface Definition, it is then the SDongle that...
There is some light coming! I got reply from Huawei support today, and it turns out **there is no automatic address allocation** - at least not for this purpose (I...
Yes, but only with one of my two cascaded inverters (but that is a separate issue). With SPC 124 there is a setting to enable Modbus TCP, as it is...
> Thanks for your comment. > > I upgraded to SPC124, but still I can't do step 8. This option is not available.. > > I have now approached the...