Results 99 open-grid-emissions issues
Sort by recently updated
recently updated
newest added

Some plants are not assigned a BA and are assigned an artificial BA like MS. - [ ] Why aren't these plants being assigned a BA? - [ ] What...

question
data outputs
eia
regional aggregation

The combustion of biomass releases greenhouse gases and other air pollutants into the atmosphere. However, the EPA's eGRID database includes a legacy calculation of biomass-adjusted emissions values. As they explain...

question
methodology
epa
emissions

A handful of units that report to CEMS only report NOx emissions data, but report zero data for gross load, fuel consumption, and other pollutants. As of https://github.com/singularity-energy/hourly-egrid/pull/133, we now...

data repair
hourly profiles
emissions

For its table of boiler type-specific NOx emissions factors, eGRID uses this table from EIA for emissions factors: https://www.eia.gov/electricity/annual/html/epa_a_02.html. However, where there is not a specific NOx emission factor in...

question
epa
emissions

We assume that measured and reported NOx emissions in CEMS represent controlled NOx emissions (rather than uncontrolled) - that is, NOx emissions after emissions control equipment has been used. In...

question
epa
emissions

Currently, we fill missing CO2 emissions data in CEMS, which we identify as data that is missing, or is reported as zero when fuel consumption is non-zero. However, we do...

data repair
emissions

Fossil fuel power plants have a startup period between between a period of inactivity and the start of normal operations. During these startup periods, there are differences in plant operations...

dependencies
methodology
data repair
data outputs
gross-to-net generation
hourly profiles
emissions

Plant 7063 is a compressed air energy storage project that operates on natural gas turbines. Because the prime mover is listed as `CE` for compressed air storage, there is not...

question
data repair
emissions

Currently, when allocating `fuel_consumed_mmbtu` and `fuel_consumed_for_electricity_mmbtu` from the EIA-923 Generation and Fuel table to individual generators using the `pudl.analysis.allocate_net_gen` module, we allocate both using the same fraction. However, in reviewing...

question
methodology
data repair
eia
emissions

When calculating consumed emissions for BAs that import electricity from foreign balancing authorities in Canada or Mexico, we need to know the interchange volume with the foreign BA and the...

dependencies
methodology
data repair
data inputs