LAURA SCALZO
LAURA SCALZO
Hi all, I want to add some details on the root cause that causes the issue. During the test, the TCL send the command Relay MAC command : 0x43 -...
[TP_RELAY_EU868_ED_MAC_104_BV_003.zip](https://github.com/user-attachments/files/20365026/TP_RELAY_EU868_ED_MAC_104_BV_003.zip)
Hi, I can confirm that the issue occurs in a controlled environment. I can add that the issue occurs always in steps 6 or 7 or 8 when a MAC...
[TEST_03_FAIL.zip](https://github.com/user-attachments/files/20393776/TEST_03_FAIL.zip) Hi, this another example of FAIL. The FAIL is at step UpdateUplinkListReq. The MAC command with size 40 byte is sent by the TCL to the Relay.  It...
Hi, thank you for the comment. I know in some cases it is necessary, but, for me, not in these all cases. For example, if a task expires and it...
Hi, the case mentioned in the previous comment is related to an expired task and in running state. I found the root cause of the expiration of task, by the...
[FAIL_TP_A_EU868_ED_MAC_104_RETRANSMISSION_BACKOFF.zip](https://github.com/user-attachments/files/21318045/FAIL_TP_A_EU868_ED_MAC_104_RETRANSMISSION_BACKOFF.zip)
Hello, I didn't disable the certification mode, but this should not impact the backoff test. The test steps are only related to join and to count the join requests. No...
Hello, Seems also that there is logic to consider the Duty Cycle periods of 1h, 10h and 24h. Seems it is implemented only to cover the 1h period. Any comments...