Just to not confuse you the file I sent is different from the image though :).
Hi @fujiisoup, Thank you for looking this up. That's quite unfortunate that timestamps are not recorded in the fast kinetics mode. If I understand you correct, the accuracy for the...
I see. So that should also imply that the readout is equally spaced I guess?
Thank you for clarifying this. I appreciate your time :). -Sabyasachi
Hi @fujiisoup, I am still confused as to why the cycle time is 36.2 us. My exposure time was 10 us and the vertical shift time was 0.6 us. So,...
I guess then I don't completely understand what exactly cycle time refer to. I thought it referred to the rate at which each frame is acquired as depicted in the...
I shall check that and let you know. Most probably that should be possible. But this is what I understand from the proposed experiment: The blinking time should co-incide with...
Hi @fujiisoup, I have an update about the Fast Kinetics Mode. So, in this mode, we get an extra 20.71 us for every configuration. What I mean by this is:...