If the sensors are only 200m apart, readings should be similar, hyper local pollution gives irregular high peaks I would not expect structural differences. I would guess the other sensor...

Nice tests! I also have multiple kits (7), the pm2.5 values are pretty similar but I do have differences in pm10. My appoach for the humidity issue is to use...

Hi Roger, I use the sds011 sensor, the Dutch institute for health and environment (RIVM) recommends this sensor for citizen science initiatives. In the current 6 kits I use a...

I checked the link, it's quite a theoretical story! I used a more practical approach. My goal have solution that works the entire year, so the problem with solar power...

![sensor](https://user-images.githubusercontent.com/39745178/52444520-e60feb80-2b28-11e9-929a-d3340a5e9b28.jpg) It's still experimental: the inlet is a 9 cm copper tube (8 mm) glued to the SDS011. 20 cm constantane wire (100 ohm/m) is wrapped around the copper tube...

Still work in progress, unfortunately it's more complex than simple heating. Heating in general does improve the correlation with reference sensors (about +5%). The downsides are that you need a...

Check out https://amt.copernicus.org/preprints/amt-2019-422/amt-2019-422.pdf , much of the output is just calculated. In our project we use only the PM2.5 results of the SPS30. We prefer the SPS30 over the SDS011...

I had the same issue with one sensor, I just let it run to see what would happen. After about 8 hours it went back to normal. I cheched the...

That's more than 2 days... ☹

Good point! Would be nice to have an offset option for all sensors.