rhammen

Results 89 comments of rhammen

So what is the next step with this open issue? What is expected of the luxtronik integration on this subject? My interpretation of this 'issue'/request is: - some people want...

> And another idea: Do we need an extra thermostat for cooling? Or should it be handled with the same heating thermostat? I can imagine one combined heating/cooling thermostat that...

Sorry, but I really think the cooling thermostat should set the cooling_threshold_temperature: "parameters.ID_Einst_KuehlFreig_akt". This is the main parameter that determines if the heatpump should start cooling or not. At my...

> I looked at this feature and I think it does not work well with my heatpump. > > When I change the temperature from 20C to 21C using the...

I have an Alpha-Innotec Brine/Water heatpump. I do not have a separate electricity meter, so I cannot really judge the heating=off power usage. But I do not see periodic spikes...

I'd say it looks pretty good! My (porbably oversimplified, but still) view: - Inverter lifetime relates to start/stops --> less start/stops is better - Heatpump efficiency is best with a...

> Is there a setting that allows to decrease `flow temperature`? To my best understanding, changing the heat curve sets the `return target`, so I tried to lower and flatten...

In the proposed changes I added sensors for both: - "parameters.ID_Sollwert_KuCft2_akt" --> = target water temperature used during cooling - "parameters.ID_Einst_KuehlFreig_akt" --> = outdoor temperature threshold. Cooling starts only if...

I'd say we now have a working thermostat. The thermostat allows to set the outdoor temperature above which cooling will start. I think some documentation - explaining the usage -...

I will try to implement a heating thermostat as discussed in another thread: > So we can only control the thermostat via "parameters.ID_Einst_WK_akt" That means: > Is this how you...