Victor

Results 645 comments of Victor

> I copy the Bindkey from above, paste and Set EEP Bindkey. Bindkey must be registered in MiHome on a thermometer with official firmware. Only after that the device is...

Help solve these problems: * Disabling the data refresh transmission command on the LCD does not save power. * There is no documentation for LCD controllers. * There is no...

[TLSR8251F512ET24](http://wiki.telink-semi.cn/doc/ds/DS_TLSR8251-E_Datasheet%20for%20Telink%20BLE+IEEE802.15.4%20Multi-Standard%20Wireless%20SoC%20TLSR8251.pdf): Supply voltage 1.8 - 3.6V [SHTV3, SHT4x](https://sensirion.com/products/catalog/): Supply voltage 1.08 - 3.6V Didn't do any specific tests. But during the fuss with them, 5V power was supplied more than...

USB powered operation (5V): ![image](https://user-images.githubusercontent.com/12629515/155865454-3f027771-5c9e-4040-92cc-702cb3f0b4bb.png) I do not recommend repeating, but if desired, it works with a slight increase in the total current consumption ... :) The reliability of the...

![image](https://user-images.githubusercontent.com/12629515/155866344-98d015b8-786b-4485-80f3-ee949332edee.png) At 3.6V, something triggers in the chip and the current rises... ![image](https://user-images.githubusercontent.com/12629515/155866389-ed93b3e6-245f-48e9-b0b0-8becda0acefa.png) ![image](https://user-images.githubusercontent.com/12629515/155866382-41423343-5c59-48b6-afff-d596e8afc0aa.png) ![image](https://user-images.githubusercontent.com/12629515/155866511-69d158b9-d5f1-4b34-8a7e-c7cb87ab4f28.png)

The version is determined by the addresses of the display and sensor on I2C HW | LCD I2C addr | SHTxxx I2C addr | Note -- | -- | --...

HttpClient works with TCP2UART: http -> TCP-UART Settings -> Client/Server IP: ext. ip HttpClient a URL to GET / POST requires specialization by each task...

The number of displayed digits is specified in the integration settings used in Home Assistant. Example, description for integration with a [passive BLE monitor](https://github.com/custom-components/ble_monitor): https://custom-components.github.io/ble_monitor/configuration_params#decimals

With limited accuracy and data coarsening, instead of a smooth normal graph, we get squares. The sensors used in the thermometer give a relative accuracy better than 0.1% of full...

> Sadly this is not possible with [BTHome](https://bthome.io) (which is available since HA 9.0). BTHome is per default on HA 9.0, which makes it super easy and flawless for using...