I tried restarting the whole system, the usb adapter and the boiler are the only devices on the bus. ebusd then gets the signal again but it does not change...

I noticed that, later I cloned the ebusd-configuration repo and was pointing the daemon to it's path. This stopped the unknown message errors in the log, but since then ebusd...

@mf76130 Can you post the entire command you are running or have in `/etc/default/ebusd` ? How did you tell which files you need locally?

Updated to 22.4 (deb file for buster on arm7). Checking config returns this output ``` $ ebusd -c /home/boiler/ebusd-configuration-master/ebusd-2.1.x/en --checkconfig 2022-09-22 19:29:44.457 [main notice] ebusd 22.4.v22.4 performing configuration check... 2022-09-22...

On the electrical level the bus signalling looks OK. BUS+ goes to A on the esera coupler and BUS- goes to B, just to make sure - is that right?...

Thank you, I will try the readonly mode for now. What is poti and how can I adjust it? sob., 24 wrz 2022, 14:09 użytkownik John ***@***.***> napisał: > as...

I've adjusted the potentiometer and ran ebusd like this ``` sudo ebusd -c /home/boiler/ebusd-configuration/ebusd-2.1.x/en -f -d/dev/ttyUSB0 --scanconfig ``` It finds the master but fails to load a CSV file and...

I have ran it with --lograwdata again. here is the bytes on the bus ``` $ sudo ebusd -c /home/boiler/ebusd-configuration/ebusd-2.1.x/en -f -d/dev/ttyUSB0 --latency=200 --lograwdata -s 2022-09-24 21:09:22.891 [main notice] ebusd...