exoseq icon indicating copy to clipboard operation
exoseq copied to clipboard

Joint Discovery merge with main script

Open apeltzer opened this issue 8 years ago • 2 comments

In case we dont have > 30 exomes, we could simply set up the VQSR recalibration step to take 30 exome samples from 1000G and use these as calibration samples. For bigger clusters, we could even store these without having to process them every time we analyse a single exome sample.

What do you think @marchoeppner ?

apeltzer avatar Apr 19 '18 10:04 apeltzer

That would allow us to merge the jointdiscovery workflow again within a single script, making the entire process less annoying ...

apeltzer avatar Apr 19 '18 10:04 apeltzer

I would support this; we currently use in-house calbration exomes for this - we would need to make sure that we don't introduce any biases if different sequencing platforms (patterned vs non-patterned flow cells) are used (?)

marchoeppner avatar Apr 26 '18 10:04 marchoeppner