Niclas B
Niclas B
After performing more experiments, I have found the breaking-point to be somewhere between 599W (still working) and 557W (not working) (All "real" values are from the original Sparsnäs display)
Yes, that is correct. 100 pulses /KWh
> I've added a function to print raw power values to the serial port. Not tested. Not sure how I can test this. I am currently using @riksarchen fork as...
@fredrike Data4 seems to be 1 at higher loads when everything is working and 0 when at lower loads when wrong power is being reported. `Seq 18017: 1585594856, 624.72 W,...
Yes, started doing this yesterday, but only had the time to get 5 or 6 value pairs. And since the original display only shows whole watts, I think some more...
OK, Here are some readings! watt =[ 508 466 456 460 465 465 468 200 171 150 141 133 120 114 184 268 263 291 353] raw = [4530 4934...
I have now fitted a exponential model to the values I recorded and extracted some coefficients. I have successfully added it to the code and get good values even when...