mentalDetector

Results 6 comments of mentalDetector

Unfortunately I cannot view the picture you uploaded. The value of FB1 is non critical in my opinion. That's why I didn't measure its exact values. It is used to...

Thanks for noticing. I came across this KDS TCXO during the process, but KiCad didn't have a ready symbol included. I will generate one in the next update and exchange...

I took this capacitor value out of Ludich's and Manuel's table and did not measure it myself. 120 nF could still be a suitable value for a microphone circuit where...

I trust the U1252B 😃 Will close this issue when I update the schematics. I also found 100nF to be more suitable, but had to rely on work of others...

Hi jumbo5566, would you mind opening a new issue for that? How did you measure C76? Could well be an error in the schematics.

Reverse engineering a PCB is quite easy if you know what you are doing. Any broken or donor HS-02 available? Then I could help you guys out… Procedure is described...