mamontuka
mamontuka
Thank you. Im check your proposed configuration, all works with much better response
> Hi, what kind of RS485-ethernet device do you use? > > I have tried 3 different types from Waveshare and I get a lot of timeouts in my logs....
also try to do timeouts in integration config: - KEY: W READ_EVERY: 15 REPORT_EVERY: 60 - KEY: RW READ_EVERY: 15 REPORT_EVERY: 60 CHANGE_ANY: true - KEY: any_unit READ_EVERY: 30 REPORT_EVERY:...
Also, all low voltage devices - relays, rs485 gates, mikrotik router and ethernet switch - powered by low voltage UPS boards : https://proline.biz.ua/ef9012 with own 26ah lead batteries , connected...
> Since the update 4 days ago I'm getting poll errors, everything worked fine before > > Error: > > 16:09:19 ERROR OSError in callback read_ss: timeout reading 1 registers...
> I have the Single Phase Sunsynk 16KW 3x MTTP inverter on single phase Daily Charge, Daily Discharge and Daily Load - is 72,73,84 try add ovverride custom sensors construction...
oh i did mistake... in strings : Sensor(72, "Daily Charge", WATT, -1), Sensor(73, "Daily Discharge", WATT, -1), Sensor(84, "Daily Load", WATT, -1), WATT - must be KWH i think and...
> I'm getting all the Daily values, that's fine, the issue is the constant error and warning logs: > Unknown register value 80. > Other that that it's working fine...
put cable in **METER485** port. it will work by **ORANGE pair** - white-orange is B(D-) (rj45 pin 1) and orange is A(D+) (rj45 pin 2)