Ernesto Mainegra
Ernesto Mainegra
@iymadmansour thanks for letting us know! I will take a look and see what might be the issue! In principle mcdf-xcom triggers a sorting of the elements to start sampling...
@iymadmansour could you check PR #845 and check that it fixes this issue? Go to the tab `Files changed` to see the on line that needs changing in egsnrc.mortran!
@moralesjohnny and @rtownson this is only a warning issued by the job submission script `run_user_code_batch`. Jobs must still be running though. The script `config.guess` is used to determine the computer...
**Hi-res vs low-res ranmar rng timing for isotropic photon source:** - Kerma in 5 cm radius air sphere @ 1m 40 keV (egs_kerma): - ph transport only: 8% slowdown -...
@MartinMartinov thanks for sharing that info! I'm running a case for a Pb sphere and will update above. @ftessier a proper definition on when to use the hires rng might...
@ftessier if you are interested here is a bit of a soap opera I discover last night in the world of RNGs researchers: https://www.pcg-random.org/posts/on-vignas-pcg-critique.html Spoiler alert: They might be arguing...
@ftessier see above the result ranlux vs ranmar in Mortran. It is actually getting worse!
@ftessier looking forward to your xoshiro256+ implementation! 🤓
While it is true that the EGS User Guide to Mortran3 in the EGSnrc user's manual PIRS-701 (SLAC265 - APPENDIX 4) states that the line length can be increased up...
@ftessier can I get back to you on that next week? Although the fix is "trivial" I would like to test it thoroughly system-wide. There aren't that many mortran files...