John
John
does pressing the reset button help in this case?
note to myself: perform hardest possible reset if there is no wifi connection for more than a certain time
ebusd-esp is nothing more than a serial-wifi bridge. no mast/slave mode or whatsoever
[ebusd 22.4](https://github.com/john30/ebusd/releases/latest) is out and it continues to try scanning devices until successful, maybe that helps
please run "ebusctl f -h ActualRoomTempDesired" to see the hex data of the message. I guess your device answers either not at all or with an empty result.
as expected the answer from the slave is too short (1 byte only) as the temp field requires 2 bytes. So it seems your controller does not really support that...
it might be just a stupid replacement for a heat-curve-controller, so I don't really know. The value should be settable somehow, but I'd check if the heating curve is usable...
scan result (Ochsner OTE 3): 08;TEM;WE_1 ;3632;3030 15;TEM;22420;0503;0102 grab result: 01150621040080004a / 0a00800d02f4010cfe8000 01150621040081004a / 0a01800d02f40100000080 01150621040082004a / 0a02800d02e80300003a01 01150621040194004a / 0a94800200010000000100 011506210402c60040 / 0a46410428ffff0000bea4 011506210402c80040 / 0a4841042a9f0500001e03 011506210403b2004a /...
Some Ochsner messages can be found here: [ebusd-1.x.x/ochsner](https://github.com/john30/ebusd-configuration/tree/master/ebusd-1.x.x/ochsner) In order to find more message definitions, you just need to analyze all the unknown messages logged by ebusd and find the...