I have this enabled and restricted to my monitoring IP. I will try to figure out how to send write requests via modbus tcp to the inverter. I am really...
I am trying with a simple `result = c.write_register(47088, 8, unit=0)` This should change the maximum charge level of the battery and is displayed as a rw value in the...
So, regarding SPC124 and latest version of FusionSolar Android App. Yes, It can definitely be enabled, even without sunlight. I enabled it last weekend and just changed settings when the...
This is my environment: SUN2000-5KTL-L1 V200R001C00SPC115 SDongleA-05 V100R001C00SPC124 Android app latest version
> Do you know if the modbus-tcp configuration requires an installer account? I definitely log into the inverter using an installer Account. You can find the specific settings in Settings...
I am rolling back inverter and dongle versions. I upgraded to inverter fw117 and sdongle 126 and i was getting no responses from the SUN2000.
I have successfully jumped back and forth firmware versions using fusionsolar > Plants > Device > Upgrade Management. You can ask inverter support email for the required firmware version and...
Following up on this. I sent an inquiry to Huawei and got the following response: _Hello, Please upgrade the SDongle to V100R001C00SPC124 and enable the Modbus TCP according to the...
I currently monitor the inverter using another app via modbus-tcp. However If I try to connect HA also to the same modbus IP/port, everything collapses and it stops responding. Is...
Yes, I recently upgraded the dongle to a newer version, but that was a couple of months ago, I have sent support an email asking for any updates. Thanks