jantenhove

Results 10 comments of jantenhove

Thanks for the detailed logs. It looks like the watchdog timer resets the ESP. I am currently testing a version that compiles with the latest ESP boards version. Maybe this...

Too bad. The latest boards version did not fix this issue. (commit da44ff3) I will add extra (remote) logging too see what causes the wdt reset.

Adding extra yields+using a clock speed of 160Mhz seems to fix this problem. Howevers problem #16 still persists.

I also noticed this recently. I added some extra debug info, but I'm still unable to catpure the stops. It's hard to guess when and where it stops without logs.

The inverter has a 10 minute timeout for connected RS485 devices. When the ESP 'thinks' it is no longer connected to the inverter it restarts the discovery. When the inverter...

Thanks for the debug log. You stopped logging too soon however :) The inverter did not respond on the request for information. When this happens the inverter will be marked...

I also have this issue., after 2 years of flawless functioning. So far I have tested the following - Changed interval to 10 seconds, detection interval if one inverter is...

I modified the RemoteDebug a library a bit. The modified version can be found here: https://github.com/jantenhove/RemoteDebug

Hi @WeeJeWel , Sorry for my late response. Which meter are you using? I've used this sketch on multiple meters. Some meters use 9600n8, some 9600e7, some are inverted, and...

Does the patch from https://github.com/keylase/nvidia-patch/ work to increase the number of Cuda encoding sessions? You can check this with ffmpeg.