Hello, I do not see the changes in the development branch, is this PR for revision? Grateful for your time,
Hello, This routine is implemented in the S7Optimizer, I have carried out tests with the default PDU which is something around 400 bytes and I have not found any problems....
Hi, I was able to see the problem, tested with a S7-400. I think it may be the "Return code" in the "Item" section, currently 0x77 and should be 0x00....
Hello, Just to discard If it is an S7-300, it should be String url = "s7://XXX.XXX.XXX.XXX.:102?remote-rack=0&remote-slot=2"; If it is an S7-400, String url = "s7://XXX.XXX.XXX.XXX:102?remote-rack=0&remote-slot=3"; So, Are you using NetToPLCSim...
Hello, This exception is generated internally by Netty when initiating the connection and should not affect the general operation of the driver. Greetings,
Hello, Perform the tests with 0.13.0-SNAPSHOT against an S7-1200 (1214C) without problems connecting or reading data. Use the same example for S7-1200 available in the repository. Kind regards,
Hello, Perform the tests with 0.13.0-SNAPSHOT against an S7-1200 (1214C) without problems connecting or reading data. Use the same example for S7-1200 available in the repository. If you agree we...