Denys Melnyk
Denys Melnyk
@mwittrien Any info on this?
@jdabhi-hah The issue you're encountering is due to the HL7 version specified in your message. The CON segment, which you're using for consent information, is not supported in HL7 version...
@jdabhi-hah It seems that the ADT message might not be fully compliant with the HL7 specification. As a workaround, I recommend making a couple of modifications to your string before...
@jdabhi-hah You can try this one: https://github.com/germiBest/hl7apy/tree/con-segment-to-v2.3 It's in branch `con-segment-to-v2.3` in my personal fork. I've just copied the CON segment and all its requirements from v2.5 to v2.3, this...
For Q1: The individual segments are valid, but the overall message structure is not. In an ORM_O01 message the HL7 standard (and HL7apy’s ORM_O01 profile) expects that after the MSH...