eth_supermegabot icon indicating copy to clipboard operation
eth_supermegabot copied to clipboard

Using the SMB 261 VI sensor

Open dwisth opened this issue 5 years ago • 2 comments

Here's the rough method we figured out for resetting the VI sensor reliably if not working:

  1. Close all ros process running.
  2. Kill any existing DHCP clients. ps aux | grep dhclient sudo kill -9 <process number> as many times as required.
  3. Reboot the VI sensor. ssh [email protected] reboot wait approx 20 seconds. Check it has rebooted with ping 10.0.0.1.
  4. Restart the DHCP client: sudo dhclient enx<tab complete here>. This takes time.
  5. Start the launch files now.

The main problem is that the VI sensor is DHCP master so the PC needs to request an IP from the sensor.

dwisth avatar Jun 30 '19 09:06 dwisth

our new awesome launch file. new_awesome_launch_file.launch.txt

dwisth avatar Jun 30 '19 09:06 dwisth

Thanks a lot @dwisth We added this in #27, but it needs to be tested on the robot.

gawela avatar Jul 03 '19 15:07 gawela