eth_supermegabot
eth_supermegabot copied to clipboard
Using the SMB 261 VI sensor
Here's the rough method we figured out for resetting the VI sensor reliably if not working:
- Close all ros process running.
- Kill any existing DHCP clients.
ps aux | grep dhclient
sudo kill -9 <process number>
as many times as required. - Reboot the VI sensor.
ssh [email protected]
reboot
wait approx 20 seconds. Check it has rebooted withping 10.0.0.1
. - Restart the DHCP client:
sudo dhclient enx<tab complete here>
. This takes time. - Start the launch files now.
The main problem is that the VI sensor is DHCP master so the PC needs to request an IP from the sensor.
our new awesome launch file. new_awesome_launch_file.launch.txt
Thanks a lot @dwisth We added this in #27, but it needs to be tested on the robot.