Ali Yousaf
Ali Yousaf
> an update: I commented `// pClient->setMTU(517);` > > and it is solved, can anyone explain how this might effect the communication between the two terminals? thanks again As long...
Thank you for quick reply. I will work on the suggestion provided above. Meanwhile please kindly take a look at the logs attached below: [tpms_json.txt](https://github.com/user-attachments/files/15989346/tpms_json.txt) I am using ESP32 Dev...
Attached are some more codes as requested. With usual timings, codes grabbed with `rtl_433 -R 0 -X 'n=name,m=FSK_PCM,s=50,l=50,g=150,r=900,preamble=5556' [rtl-433-R0-X.txt](https://github.com/user-attachments/files/16011687/rtl-433-R0-X.txt) Using URH, recorded the waveforms: [RTL-SDR-20240627_143405-433_92MHz-1MSps-1MHz](https://drive.google.com/file/d/1QpQqq-id1dfM9P9A-417C2Cddi2HSX4Y/view?usp=sharing) _Comments on waveforms:_ First 3...
looks interesting. Been working on decoding pressure data. Any hints on that one? data doesn't seem to be in kPa... 0x1F9 to 21 PSI ?
> I reviewed the rf decode part, it works fine a with FSK_MC_ZEROBIT , pulse is 54 µs and preamble = 0xfffff5, try the sample with: > > ``` >...
[tpms_chinese.zip](https://github.com/user-attachments/files/16069773/tpms_chinese.zip) drafted the decoder based on above finding by @ProfBoc75 . Using [RTL_433_ESP](https://github.com/NorthernMan54/rtl_433_ESP/tree/main) library, I was able to get the codes after some tuning of CC1101. `pulse_slicer_manchester_zerobit: Unbranded Chinese TPMS...
Regarding packaging, I could not find any box as they were in my garage for a long time, I don't even know where they came from. No markings or labels...
Disassembled a sensor, there is written "kylin-wz-1.0" on the PCB nothing else. I suppose we can go with this name for the device.