bluberly

Results 5 comments of bluberly

I can reproduce the fast flipping of values for heat curve office, DWH temperature but even whisper mode as well in Home Assistant. It first happened when I tried to...

@michalwoz yes, I meant the quiet mode. @geduxas I spent quite some effort to localize the heishamon HA code in this repository, changed entity names and created quite some derived...

Well, my changes to the original code are not worth to share, I added unique_id's and localized them to German language. The work went into derived values, such as COP...

Would it technically be possible to change the pump flow rate while the heatpump is running? On the remote control it only is possible when the heatpump is off. Yes,...

Hmm, my Jeisha does not reduce pump flow rate at high outside temperatures. Outlet temperature in my config is d-t controlled. My pump flow at 2400rpm is around 19.11 l/min....