十五楼的鸟儿

Results 11 comments of 十五楼的鸟儿

1、form 1~4 , my input is double PPPP = -0.96900795620149793; *1000, IT‘s -969Pa。This value is expected to be out of range。 2、1)2) got exception in C# , because out of...

> For 4), it works because your input argument is temperatureCompIn rather than PPP. If I understand correctly, that is. > […](#) > Message ID: ***@***.***> I had already edit...

but when i call refprop in excel,with formula : =Temperature("PROPANE","PQ","C",-0.000969007956201497,1) it's show error “#[PQFLSH error 4] one or more inputs are out of range: pressure < 0, P =-0.96901E-03 MPa...

> It is not true that CoolProp does not implement the SETREFdll function of REFPROP. But it is true that the default reference state is not set to match that...

This is a help document written in Chinese。 这是一份中文的帮助文档。 作者/Author @birdol Url:[https://www.birdol.com/cainiaobiancheng/24.html](https://www.birdol.com/cainiaobiancheng/24.html) ``` 主要方法来自于这里: http://www.coolprop.org/coolprop/wrappers/Csharp/index.html#user-compiled-binaries 补充了一些踩坑过程。 〇、依赖 来源:http://www.coolprop.org/coolprop/wrappers/index.html#wrapper-common-prereqs 编译过程需要依赖这些东西: git (to interface with the CoolProp repository at https://github.com/CoolProp/CoolProp) python (to...

compile c# glue code your self, this will be solved

emm....I don't know how to determine what data coolprop uses

> Furthermore, we used the ASHRAE Handbook 2001 - maybe the data changed in the meantime? According to my current verification, you are correct. The content in the ASHRAE Handbook...

In the 2021 version of the handbook, only the data source is indicated as ``Source: Dow Chemical 2001b.`` No detailed information.