Results 16 comments of Justin Huang

## Test result Test PASS in GUI part, the mode can separate original vlan and trunk, and trunk setting works well. Will use https://github.com/harvester/harvester/issues/766 to verify the function part ##...

## Test result Test FAIL, the terraform can't run. ## Environment * Harvester ISO version: `v1.6.0-rc5` * Terrafrom-provider-harvester: [f69ca13](https://github.com/harvester/terraform-provider-harvester/commit/f69ca13e2035f05a2a6f46cb936433a5d00d982e) * Underlying Infrastructure (e.g. Baremetal with Dell PowerEdge R630): `1 node...

## Test result Test PASS, the terraform-provider-harvester can run without issue ## Environment * Harvester ISO version: `v1.6.0-rc5` * Terrafrom-provider-harvester: [[f691469](https://github.com/harvester/terraform-provider-harvester/commit/f691469f89ce924cd66115d823931d999933b5e0) * Underlying Infrastructure (e.g. Baremetal with Dell PowerEdge R630):...

# Automation Test for VM operations. Test PASS ## Environment * Harvester ISO version: `v1.5.2-rc1` * Underlying Infrastructure (e.g. Baremetal with Dell PowerEdge R630): `3 node Baremetal` ## Test Steps...

## Test result Test FAIL, the Volume count of Dashboard become not equal to Volumes after upgrade. ## Environment * Harvester ISO version: `v1.6.0-rc1` * Underlying Infrastructure (e.g. Baremetal with...

Hi @a110605, In the reproduce steps you provides, the issue is gone. But I checked the result after upgrade, which is this issue mentioned, the issue still exist.

After clarify with @Vicente-Cheng and @a110605 , the volume 1 on https://github.com/harvester/harvester/issues/8405#issuecomment-3056276237 is caused by volume which is created by `harvester-system` for upgrade process. After click `dismiss it`, the volume...

## Test result Test PASS, the Volume count of Dashboard is equal to Volumes after upgrade finish (after clicking `dismiss it`). ## Environment * Harvester ISO version: `v1.6.0-rc1` * Underlying...

Test PASS, the `sans` config works. ## Environment * Harvester ISO version: v1.6-0b761d0c-head * Underlying Infrastructure (e.g. Baremetal with Dell PowerEdge R630): 1 node with ipxe-examples ## Test Scenario 1....

# Enable/Disable descheduler add-ons, and upgrade test ## Test result Test Fail, the `descheduler` add-ons is still disabled after upgrade, even it is enabled before upgrade ## Environment * Harvester...