In macOS, you only have the option to choose between flatbed and ADF. To scan multiple pages from the ADF, choose PDF as output format, and check "Scan into single...

>For including your software in debian Cool, thank you! >I suppose you have done a clean room implementation. Could you certify that you have done correctyl and legally the reverse...

In the meantime, the eSCL protocol has been officially published at https://mopria.org/mopria-escl-specification This might mitigate any concerns you have regarding reverse engineering.

No, the scanner cannot be set manually. If it is not recognized by SANE, it is not seen by AirSane either. It could be a permission problem, as AirSane runs...

409 means "Hardware Conflict" and, in this case, indicates that SANE reports an empty ADF.

ADF support is broken in AirSane. @ShadesJeff has created a fork that is supposed to fix it: https://github.com/ShadesJeff/AirSane. Maybe you give that a try?

What does ``sudo -u saned scanimage -L`` say?

Could it be that you created a loop by not excluding airscan:.* and escl:.* scanners?

In v3.4.0, there was a bug, ignoring that SANE parameter settings might interfere with each other, i.e. setting one parameter could result in changes to other parameters. Since v3.5.0, SANE...

Thanks for your offer to help with debugging. Could you post one of the distorted scans? Also, please give me some time to go back to @meiser79 's issue #40,...