AixLib icon indicating copy to clipboard operation
AixLib copied to clipboard

A Modelica model library for building performance simulations

Results 100 AixLib issues
Sort by recently updated
recently updated
newest added

The casing of the file name here: https://github.com/RWTH-EBC/AixLib/blob/feb8ebf64bfd64931e3ff0c15ddce73c4d10f9da/AixLib/package.mo#L145 doesn't match the casing of the actual file: https://github.com/RWTH-EBC/AixLib/blob/development/AixLib/Resources/Images/Icon_Modelica_AixLib.png Note the lower/uppercase `L` in `AixLib`. This means the logo will not show...

With the updated CI, the separation of dev and master is not required anymore. This will also enable smooth use of squash and merge. @DaJansenGit @SvenHinrichs Will you handle this?

CI

Hi, I am a new user of OpenModelica. When I try to load PropulsionSystem library, I get the error like below. Thank you so much. ![Error](https://user-images.githubusercontent.com/118957205/203797816-c38588e8-e313-42fc-9d00-8d459ca5921f.png)

> Thank you for making a Pull Request to AixLib! > Please consider these points before submitting: > - Mention the issue that this Pull Request intends to solve, and...

These lines use `` on Reals, which is only allowed inside functions: https://github.com/RWTH-EBC/AixLib/blob/f2c600fe7a145916dbb7326a35cf7f96a7edd0aa/AixLib/DataBase/Pumps/PumpPolynomialBased/Examples/testMaxMinHeightTable.mo#L29 https://github.com/RWTH-EBC/AixLib/blob/f2c600fe7a145916dbb7326a35cf7f96a7edd0aa/AixLib/DataBase/Pumps/PumpPolynomialBased/Examples/testPumpPowerCalculation.mo#L51 https://github.com/RWTH-EBC/AixLib/blob/f2c600fe7a145916dbb7326a35cf7f96a7edd0aa/AixLib/DataBase/Pumps/PumpPolynomialBased/Examples/testPumpHeadCalculation.mo#L54 https://github.com/RWTH-EBC/AixLib/blob/f2c600fe7a145916dbb7326a35cf7f96a7edd0aa/AixLib/DataBase/Pumps/PumpPolynomialBased/Examples/testPumpHeadCalculation.mo#L61 https://github.com/RWTH-EBC/AixLib/blob/f2c600fe7a145916dbb7326a35cf7f96a7edd0aa/AixLib/DataBase/Pumps/PumpPolynomialBased/Examples/testPumpSpeedCalculation.mo#L63

**What is the problem?** - For control algorithm testing, a model with a zone supplied by a ahu and a concrete core activation is needed. **How do we want to...

Valid standards: DIN EN 12831-1:2017-09 + DIN/TS 12831-1:2020-04

The model `AixLib.ThermalZones.HighOrder.Rooms.BaseClasses.PartialRoomParams` contains a connector, even though it should only contain parameters. Further, the `wallTypes` could use the information about thermal insulation regulation to set n50 and U values...

hackday