Hi Fernando, thanks for your timely response! I am adding Gaussian noise to the signal after calculating the electrode potential. I know this isn't physiologically equivalent to real recordings as...

Since too little noise and too much noise does not help detection, I have set the Gaussian noise below to half a standard deviation of the signal. ![image](https://user-images.githubusercontent.com/62302767/159718352-a21c41b8-eb96-4937-995b-d9962759d2f5.png) I think...

Hi Fernando, I have a couple of questions about wave clus I was hoping you could help resolve. Firstly, do you happen to know why I may be getting this...

Hi Fernando. thanks for getting back to me so soon! I am uploading .mat files like those I have attached in the zip folder consisting of a single 1xN sample...

As seen in the sc below, the amp_detect function seems to run but looks like iaux and i are empty vectors. Could this be why the problem is occurring? I...

Hi Fernando for clarification must par.ref_ms be set to at least 2*1000/par.sr to satisfy the Nyquist frequency? because wave_clus worked when I set it par.ref_ms to 28.

Saludos Fernando! Perdon, pero no me habia fijado que usted es de Argentina! Me alegro mucho que haya una buena communidad de cientificos hispanohablantes en esta área de investigación. Bueno,...

Hi Fer, You said par.pre and par.post don't affect the detection but do I have to vary them if I change anything like my sampling rate because they don't seem...

Hi Fer, sorry for the constant messaging Firstly I wanted to understand why you said the following in your previous comment: > wold increase par.ref_ms, check that each spike is...

Hi Fer, I was wondering how the times for each spike in the times_[filename].mat file are aligned? Is it aligned on the spike peaks or could it be affected by...