In my experience, from several different tools, mass flow sources and sinks easily lead to non-physical behavior, such as pressures close to (or below) zero, but that pressure sources with...
Thank you for pointing this out, in Dymola there isn´t even a warning. I will look into it, but since it is outside my comfort zone, it might take a...
I think the function call should be Modelica.Units.SI.Density liquidDensity=Medium.Liquid.density(Medium.Liquid.setState_pTX(medium.state.p,medium.state.T,{1})) "density of the liquid in the tank"; Modelica.Units.SI.Density gasDensity=Medium.Gas.density(Medium.Gas.setState_pTX(medium.state.p,medium.state.T,{1})) "density of the gas in the tank"; This simulates in Dymola. But...
The above suggestion does not work. The least restrictive base classes that still work without giving other problems are replaceable package Gas = ThermofluidStream.Media.myMedia.IdealGases.Common.SingleGasNasa; replaceable package Liquid = ThermofluidStream.Media.myMedia.Incompressible.TableBased; The...
* To further improve this we might consider using corrected speed and mass flow rates https://en.wikipedia.org/wiki/Compressor_map for compressor curves This is the form in which we usually receive component data...
Sorry if I am a bit confused. I tried to applaud your suggestion on using corrected speed and corrected flow as an answer to the mail sent on #217, where...