Is the pleora simulator freely available ? Could you attach the output of `arv-tool-8 values` ?

Hi, Did you check exposure time is small enough ( < 33 ms ) ? Could you attach the output of `tests/arv-camera-test -f 30 - e 30000 -d all`, please...

Looking at the log file, packet transmission from the camera to the machine works fine. It is probably an issue when aravis tries to set up the acquisition frame rate....

This is another occurence of the Genicam legacy mode issue. Please try this workaround: https://github.com/AravisProject/aravis/issues/444#issuecomment-730263537 Please attach the Genicam data of your camera, obtained using `arv-tool-0.8 genicam`.

> I think I know what the problem is, the xml has some strange characters like ’, ° and µ and the genicam's xmlParser is not able to handle them...

One last thing. Could you please update Aravis to the latest version, and attach the output of `arv-camera-test-0.8 -d all` ? That will provide some additional informations about the legacy...

So it looks like it works when a GigEVision register write command is used instead of memory write. Could you try to force the legacy behaviour by modifying _register_workaround_check and...

Hi Zachary. Could you check if WriteMem commands are supported please ? This command should give you the answer: ``` arv-tool-0.6 control GevSupportedOptionSelector=WriteMem GevSupportedOption ```

@zackwyatt Please report this issue to pleora. They should not advertise 1.1.0 schema version if they do not support 4 bytes writemem commands. @roimr Please open another issue for your...

Blast from the past... In the Genicam documentation: ``` 3.1.1 Behavior of products based on schema version 1.1 and newer Cameras providing XML file based on schema version 1.1 or...