Emilv2
Emilv2
@EmAnzi3 Do you want to read one inverter from slave 1 and the other from slave 2, or do you want to read from different slaves on one inverter?
Does this not work, or am I misunderstanding you? ``` sensor: - platform: huawei_solar host: '192.168.0.123' battery: true slave: 1 - platform: huawei_solar host: '192.168.0.124' battery: true slave: 2 ```
I think that shouldn't be too complicated. Are you saying your can also read out optimizer data this way?
Ok, I see now what you meant. I'm thinking about how to specify which register value should be used with which slave without making the configuration overly long, any idea?
> Checking values between Fusion Solar app and HA I can only say that Total/Daily Yield are underestimated in HA, same for batteries charge/discharge. I don't see how that is...
I'm not sure what is going on there, all the state and attributes values are update in one function call. There is no way to update one without the other.
Yes, I don't see how deleting it would change anything. I have rewritten a lot of the code of this sensor, does the issue still occur with the latest version?
If the connection is broken the values should be invalid and not 0, I'm not sure why this did not happen here. That said, I don't have much time to...
Total yields are not supposed to reset, better use those instead of the daily ones.
Use total yield, total charge and total discharge